Diaphyseal stem
WebSep 1, 2024 · Contemporary diaphyseal engaging revision femoral stems often have a modular proximal body and fractures were reported at the modular junction, particularly with earlier stem designs [2], [4]. Modular junctions are also used to combine a metaphyseal sleeve with a diaphyseal engaging stem allowing independent control of version to … WebMethods: This was a retrospective study involving 36 patients who underwent hip arthroplasty with a metaphyseal-diaphyseal fixation stem (standard length stem) and had indications for hip revision, which was performed with a proximal press-fit short-stem prosthesis for each patient. Dual-energy X-ray absorptiometry (DEXA) was used to obtain ...
Diaphyseal stem
Did you know?
WebThe stem then should be inserted with or without cement, depending on the preoperative plan. In most fractures, the stem will be stable, and the final result will not be compromised. If the fracture propagates, converting this into an unstable Type A 3 fracture, then a diaphyseal-fitting stem should be used. 60,64,81 WebThe short metaphyseal rTSA design without a diaphyseal stem shows encouraging short- to midterm results, with excellent pain relief and shoulder function, restoration of good active range of motion, and high patient satisfaction scores. The design of this implant seems to result in improved rotation …
WebJan 4, 2024 · The technique to prepare the femoral canal for the stem implant utilizes broaching alone for the metaphyseal fitting stems, … WebThen an S-ROM stem was implanted to match the straight and narrow diaphyseal canal. Although the femoral proximal medullary canal of type IVB DDH was closer to the normal, the S-ROM femoral component was still recommended because of the excessive anteversion and anteroposterior diameter of the femoral proximal medullary canal.
WebMay 8, 2024 · A short stem with slightly smaller diameter (simulating a less stiff stem which still has diaphyseal fixation) increased the proximal bone deformation, but also tended … WebThe objective is to evaluate the results of the modular revision stems with diaphyseal anchor and distal block (Revitan Zimmer Biomet GmbH, Winterthur, Switzerland). Our hypothesis is that this procedure offers a stable primary fixation in cases of alteration of the femoral isthmus.
WebJun 5, 2024 · National Center for Biotechnology Information
WebCorrespondence: Pavel Sponer Tel +420 495 833 566. Email [email protected]. Introduction: The present study compares the outcome of the long cemented stem and the revision uncemented stem used in periprosthetic femoral fractures. We propose that the revision with a long stem cemented prosthesis does not compromise fracture healing. black and mild customer service numberWebIntroduction. Diaphyseal femoral fractures occur in both the young and the elderly. Their causes are diverse, as are the treatment options used to treat both the fractures and the associated injury. 1 Current methods include intramedullary nailing, plate fixation, and external fixation. While the results are generally favorable, delayed union or nonunion … black and mild cream price singleWebMar 10, 2024 · A single trabecular metal tantalum cone combined with a long (100 or 155 mm) press fit, diaphyseal-engaging stem (Zimmer Biomet, Warsaw, IN, USA) was used in all cases to reconstruct metaphyseal bone defects (AORI 2 or greater) and to improve tibial fixation. Patients with cemented stems were excluded. black and mild date codesWebBackground: Various surgical techniques have been defined for hip hemiarthroplasty (HA), including metaphyseal vs. diaphyseal and short stem vs. long stem. The present study aims to compare outcomes of metaphyseal fixed short-stem vs. diaphyseal fixed long-stem HA in treating unstable intertrochanteric fractures in elderly patients. black and mild cream wood tipWebFeb 21, 2024 · Diaphyseal engaging femoral stems are often required for revision total hip arthroplasty (THA) due to complex anatomy. However, no studies have been performed to identify the best implant or intraoperative radiographic parameters of stability. black and mild earbudsWebOct 18, 2016 · Stemmed implants are inserted using either a fully cemented technique or a so-called hybrid technique, where the undersurface of the implant and the metaphyseal region of the stem are cemented and the distal portion of the stem is press fit tightly into the diaphysis. 49.1 Press-Fit or “Cementless” Stems black and mild factoryWebDec 1, 2016 · Tapered fluted titanium stems (TFTS) allow stable fixation in diaphyseal bone, helping the revision arthroplasty surgeon obtain a satisfactory clinical … black and mild effects on health